How to use the right oscilloscope? Basic knowledge of oscilloscope

2022-12-30
View:2775
Tags: Oscilloscope,

An oscilloscope is a device designed to test types of equipment and find faults in various electronic circuits. It is useful in long circuits, from analog circuits to radio circuits.


It is important to know the basics of how to use an oscilloscope so that you can make the most of it. Let's highlight some useful steps you should know to use an oscilloscope properly.


The first step is to use any device by turning on the power. The switch marked as power or line will be available on the device. You need to press the power on button that is available there.


The power indicator or light will appear after the device is powered.


After turning on the power button of the device, you should wait for the oscilloscope to show to a for the process.


Some of today's oscilloscopes have semiconductor-based spaces; on the other hand, some consist of cathode ray tubes that require some time to warm up before being displayed.


Both types of displays require time to warm up before they appear; therefore, you may have to wait about a minute before you can use the oscilloscope.


After the display appears, you need to be ready to find the trace. This is the first stage of using the oscilloscope, as other waveforms can be seen on the screen, but before that, you should try to find the trace.


To do this, you can operate the trigger by setting it in the center and holding the trigger fully counterclockwise.


Now, you also need to set the other controls by placing them in the center horizontally and vertically. At this point, the trace should be visible; however, if the trace is not found, it can be positioned by pressing the Beam Finder button.


The next step after finding the trace is to set the gain control at the horizontal position. The gain control should be set so that the expected trees can fill the vertical screen.


Assuming the expected waveform is about 8 volts peak-to-peak, the height of the screen in the calibration section is about 10 cm; you then need to set the gain control to 1 volt CM. The way it will be from now on will be 8 cm, which will take up the screen.


After setting the gain control, you need to set the time-based speed, which depends on what you need to see on the screen.


Let's say the waveform has a cycle time of 10 ms; then the screen might be 12 cm wide. At this point, the timing base speed will be one millisecond per centimeter.


After setting the time-based speed, you need to apply the signal and now you can see the image.


After applying the signal, you will need to adjust the trigger level to find out if it is a positive or negative edge. The waveform of the time base will be controlled by the trigger level control and then tracking will start on the waveform.


It is also important to determine if the trigger should be on a positive or negative edge so that it can be adjusted for the desired image.


Finally, with the waveform meter now available, you can readjust the vertical gain and time-based controls to obtain the desired image.


Digital storage oscilloscope operating modes.

Digital storage oscilloscopes are known for working in three modes of operation: Scroll mode, Store mode, and Hold or Save mode. Scroll mode is used to visibly display rapidly fluctuating signals on the screen. In this mode of operation of the DSO, the input signal is not triggered at all.


The purpose of this mode of operation is similar to the general procedure of CRO. After the input is completed, the trace is displayed on the screen. This mode is used to monitor the waveform and the characteristics it has. It is said to be one of the most basic modes of operation when working with a digital storage oscilloscope.


The store mode is used to store the signal in the memory and the hold or save mode helps the user to keep the data for a period of time until the data is stored in the memory. There are some other modes of operation for digital storage oscilloscopes.


These modes are refresh mode, single-shot mode, and equivalent time mode. The refresh mode comes into use when the waveform sampling rate becomes very high. Other times when this mode is used is when the waveforms of interest are repeated or almost similar. Digital storage oscilloscopes are known for producing outdated and triggered displays with long scan times.


Basic Oscilloscope Controls and Terminology.

Before operating an oscilloscope, it is important to understand the basic controls so that you can make the most of it and operate it well.


When we talk about the oscilloscope, it is a well-known fact that it requires more and more controls so that you can get the desired view of the signal.


Let's understand these controls so that we can get the waveform right: 1.


1. Vertical position in DSO.

The vertical position control on the muscle score is used to control the position of the trace.


If the signal is not a phrase, it is important to find the location of the trace. In order to measure the position of the data above and below zero, a convenient client is set up on the scale so that it can be easily measured.


The vertical position also has an equivalent horizontal position control with the help of which the horizontal position can be set. This control should be set at a convenient location so that the correct timing measurement value can be obtained.


2. Vertical Gain.

Vertical gain is a control available on the oscilloscope with the help of which the gain of the amplifier can be changed.


This is known to control the magnitude of the signal to be obtained on the vertical axis. The vertical axis signal is calibrated according to the approximate number of volts/cm. The vertical game is increased and the amplitude of the visible waveform displayed on the screen is increased by setting the vertical gain control to obtain a lower number of volts per centimeter.


The vertical game is typically set to acquire waveforms that fill the vertical plane. The waveform data field in the vertical plane should be filled as large as possible without going beyond the calibration area of the visible area on the screen.


3. Trigger.

The Trigger control is used to set the point at which the waveform can be scanned. When the incidental form has reached a certain voltage level, we need to set the trigger in a similar oscilloscope so that it can start scanning.


By doing this, the scan of the waveform starts at the same time of its cycle and also displays a stable waveform on the screen. By changing the trigger voltage, you can start the scan of the wavelength from a different point on the waveform.


With this control, you can set whether you want to set the trigger on the positive or negative edge on the waveform. This can be done with a separate switch that is provided on the oscilloscope and labeled with plus and minus signs.


4. Time Base.

The control option on the oscilloscope is used to set the timing of the screen scan speed.


In this control, a specific time is calibrated on the screen for its calibration. By doing so, the period of the waveform on the screen can be calculated.


Assuming that the full period of the waveform is completed in 10 microseconds, then the period set in approximately 10 microseconds is counted backwards from the time based on the frequency of the time period. 5.


5. Beam Finder.

Most oscilloscopes have always found functions in them for tracing. The trace may not be visible on the screen. This is where the beam finder button comes in handy, as you can simply press the button to find the presence and then adjust it to the center of the screen.


6. Trigger Delay.

It is one of the basic controls associated with the trigger function. It is called Trigger Delay because it will delay the trigger to prevent premature triggering after completing a scan that was completed before.


An oscilloscope needs the trigger delay feature because the waveform has several points where the oscilloscope may trigger. By adjusting to this feature, you can enable a stable display.


These are some of the controls you need to perform to get a basic knowledge about operating the oscilloscope. These controls function similarly to each type of oscilloscope. However, they may vary from one oscilloscope to another.


Digital storage oscilloscope measurements.

Digital storage oscilloscopes are a class of digital instruments that provide a time-based signal display. In this case, the display is more like a graph showing voltage over time than a waveform.


This feature allows for various forms of analysis that cannot be performed with a waveform display. Digital storage oscilloscopes use computer measurements, and digital storage oscilloscopes are very commonly used today.


A digital storage oscilloscope is a modern version of an analog oscilloscope. The main feature of this device is the ability to store data in memory and display it on the screen in a time scale.



How to use the right oscilloscope? Basic knowledge of oscilloscope
2022-12-30
Tags: Oscilloscope,

An oscilloscope is a device designed to test types of equipment and find faults in various electronic circuits. It is useful in long circuits, from analog circuits to radio circuits.


It is important to know the basics of how to use an oscilloscope so that you can make the most of it. Let's highlight some useful steps you should know to use an oscilloscope properly.


The first step is to use any device by turning on the power. The switch marked as power or line will be available on the device. You need to press the power on button that is available there.


The power indicator or light will appear after the device is powered.


After turning on the power button of the device, you should wait for the oscilloscope to show to a for the process.


Some of today's oscilloscopes have semiconductor-based spaces; on the other hand, some consist of cathode ray tubes that require some time to warm up before being displayed.


Both types of displays require time to warm up before they appear; therefore, you may have to wait about a minute before you can use the oscilloscope.


After the display appears, you need to be ready to find the trace. This is the first stage of using the oscilloscope, as other waveforms can be seen on the screen, but before that, you should try to find the trace.


To do this, you can operate the trigger by setting it in the center and holding the trigger fully counterclockwise.


Now, you also need to set the other controls by placing them in the center horizontally and vertically. At this point, the trace should be visible; however, if the trace is not found, it can be positioned by pressing the Beam Finder button.


The next step after finding the trace is to set the gain control at the horizontal position. The gain control should be set so that the expected trees can fill the vertical screen.


Assuming the expected waveform is about 8 volts peak-to-peak, the height of the screen in the calibration section is about 10 cm; you then need to set the gain control to 1 volt CM. The way it will be from now on will be 8 cm, which will take up the screen.


After setting the gain control, you need to set the time-based speed, which depends on what you need to see on the screen.


Let's say the waveform has a cycle time of 10 ms; then the screen might be 12 cm wide. At this point, the timing base speed will be one millisecond per centimeter.


After setting the time-based speed, you need to apply the signal and now you can see the image.


After applying the signal, you will need to adjust the trigger level to find out if it is a positive or negative edge. The waveform of the time base will be controlled by the trigger level control and then tracking will start on the waveform.


It is also important to determine if the trigger should be on a positive or negative edge so that it can be adjusted for the desired image.


Finally, with the waveform meter now available, you can readjust the vertical gain and time-based controls to obtain the desired image.


Digital storage oscilloscope operating modes.

Digital storage oscilloscopes are known for working in three modes of operation: Scroll mode, Store mode, and Hold or Save mode. Scroll mode is used to visibly display rapidly fluctuating signals on the screen. In this mode of operation of the DSO, the input signal is not triggered at all.


The purpose of this mode of operation is similar to the general procedure of CRO. After the input is completed, the trace is displayed on the screen. This mode is used to monitor the waveform and the characteristics it has. It is said to be one of the most basic modes of operation when working with a digital storage oscilloscope.


The store mode is used to store the signal in the memory and the hold or save mode helps the user to keep the data for a period of time until the data is stored in the memory. There are some other modes of operation for digital storage oscilloscopes.


These modes are refresh mode, single-shot mode, and equivalent time mode. The refresh mode comes into use when the waveform sampling rate becomes very high. Other times when this mode is used is when the waveforms of interest are repeated or almost similar. Digital storage oscilloscopes are known for producing outdated and triggered displays with long scan times.


Basic Oscilloscope Controls and Terminology.

Before operating an oscilloscope, it is important to understand the basic controls so that you can make the most of it and operate it well.


When we talk about the oscilloscope, it is a well-known fact that it requires more and more controls so that you can get the desired view of the signal.


Let's understand these controls so that we can get the waveform right: 1.


1. Vertical position in DSO.

The vertical position control on the muscle score is used to control the position of the trace.


If the signal is not a phrase, it is important to find the location of the trace. In order to measure the position of the data above and below zero, a convenient client is set up on the scale so that it can be easily measured.


The vertical position also has an equivalent horizontal position control with the help of which the horizontal position can be set. This control should be set at a convenient location so that the correct timing measurement value can be obtained.


2. Vertical Gain.

Vertical gain is a control available on the oscilloscope with the help of which the gain of the amplifier can be changed.


This is known to control the magnitude of the signal to be obtained on the vertical axis. The vertical axis signal is calibrated according to the approximate number of volts/cm. The vertical game is increased and the amplitude of the visible waveform displayed on the screen is increased by setting the vertical gain control to obtain a lower number of volts per centimeter.


The vertical game is typically set to acquire waveforms that fill the vertical plane. The waveform data field in the vertical plane should be filled as large as possible without going beyond the calibration area of the visible area on the screen.


3. Trigger.

The Trigger control is used to set the point at which the waveform can be scanned. When the incidental form has reached a certain voltage level, we need to set the trigger in a similar oscilloscope so that it can start scanning.


By doing this, the scan of the waveform starts at the same time of its cycle and also displays a stable waveform on the screen. By changing the trigger voltage, you can start the scan of the wavelength from a different point on the waveform.


With this control, you can set whether you want to set the trigger on the positive or negative edge on the waveform. This can be done with a separate switch that is provided on the oscilloscope and labeled with plus and minus signs.


4. Time Base.

The control option on the oscilloscope is used to set the timing of the screen scan speed.


In this control, a specific time is calibrated on the screen for its calibration. By doing so, the period of the waveform on the screen can be calculated.


Assuming that the full period of the waveform is completed in 10 microseconds, then the period set in approximately 10 microseconds is counted backwards from the time based on the frequency of the time period. 5.


5. Beam Finder.

Most oscilloscopes have always found functions in them for tracing. The trace may not be visible on the screen. This is where the beam finder button comes in handy, as you can simply press the button to find the presence and then adjust it to the center of the screen.


6. Trigger Delay.

It is one of the basic controls associated with the trigger function. It is called Trigger Delay because it will delay the trigger to prevent premature triggering after completing a scan that was completed before.


An oscilloscope needs the trigger delay feature because the waveform has several points where the oscilloscope may trigger. By adjusting to this feature, you can enable a stable display.


These are some of the controls you need to perform to get a basic knowledge about operating the oscilloscope. These controls function similarly to each type of oscilloscope. However, they may vary from one oscilloscope to another.


Digital storage oscilloscope measurements.

Digital storage oscilloscopes are a class of digital instruments that provide a time-based signal display. In this case, the display is more like a graph showing voltage over time than a waveform.


This feature allows for various forms of analysis that cannot be performed with a waveform display. Digital storage oscilloscopes use computer measurements, and digital storage oscilloscopes are very commonly used today.


A digital storage oscilloscope is a modern version of an analog oscilloscope. The main feature of this device is the ability to store data in memory and display it on the screen in a time scale.