34461A Keysight

Source Measurement Unit (SMU)
• ​With 35 ppm base DCV accuracy, you can measure with confidence.
• ​Small DC current ranges from 100 µA to 10 A allow you to test low-power devices.

34401A keysight

Source Measurement Unit (SMU)
• 0.0035% Basic DC Voltage Accuracy
• 0.06% Basic AC Voltage Accuracy
• 10mA to 3A Current Range
• 3 Hz to 300 kHz AC bandwidth
• Storage memory up to 512 readings

7461A/7461P/7451A

Source Measurement Unit (SMU)
• Variable integration time: 10 μs to 10 s (7461A/7461P) 100 μs to 10 s (7451A)
• High-resolution DCI measurements: 1 nA (7461A), 10 nA (7451A)
• Dual-channel DC voltage measurement

2612A KEITHLEY

Source Measurement Unit (SMU)
• Perform parallel tests for unrivalled throughput
• 20,000 readings/second provides faster test times and the ability to capture device transient performance
• Series offers wide dynamic range: 1fA to 10A and 1µV to 200V
• TSP-Link bus supports channel expansion of up to 32 units/64 channels per GPIB or IP address

34470A Keysight

Source Measurement Unit (SMU)
• 16 ppm basic DCV accuracy allows you to measure with confidence.
• 1 µA range and pA resolution allows testing of low power devices.
• Flexible automated measurements are available via USB or LAN/LXI core interface.
• Now includes digitizing and advanced triggering (DIG) capabilities.

34450A Keysight

Source Measurement Unit (SMU)
• High-contrast OLED display provides a clear view of measurement results
• The included BenchVue software license allows you to easily connect and control the instrument and perform tests automatically
• Automated measurements via USB interface

34465A Keysight

Source Measurement Unit (SMU)
• 30 ppm basic DCV accuracy gives you confidence in your measurements.
• 1 µA range and pA resolution allows testing of low power devices.
• Flexible, automated measurements via USB or LAN/LXI core interface.

34460A Keysight

Source Measurement Unit (SMU)
• 4.3-inch color graphic display shows histograms and bar graphs, allowing you to easily monitor measurements and speed statistical analysis
• 75 ppm basic DCV accuracy so you can measure with confidence
• Small DC current range from 100 µA to 3 A for testing low power devices

3458A Keysight

Source Measurement Unit (SMU)
• DC voltage (DCV) accuracy of up to 8 ppm per year (up to 4 ppm with options)
• Ultra-fast measurement speed of up to 100,000 readings/second maximizes productivity
• Storage depth of up to 148,000 readings (now standard) allows for longer data recording
/
PREV