The 86100D DCA-X performs accurate measurements of high-speed digital designs, from 50MBd to over 80GBd, on up to 16 channels simultaneously. Accurate measurements of high-speed digital designs from 50MBd to over 80GBd on up to 16 channels.
Optical Transceiver Design and Production Testing
Electronic ASIC/FPGA/IC design and qualification
Serial bus qualification, measurement, and troubleshooting with TDR/TDT and S-parameters Channel, cable, and PCB measurements
Keysight offers a complete digital communications analyzer solution that can be used in conjunction with or alongside the DCA-X. Includes clock recovery, standalone Digital Communications Analyzer (DCA-M), and software.
Model: 86100D
Name: Infiniium DCA-X Wide Bandwidth Oscilloscope Mainframe
Brand:KEYSIGHT
Category: General Electronics Test > Oscilloscope
Product attributes: Mainframe
Features
90 GHz bandwidth
Custom host for optical, electrical and TDR/S parameter analysis
100 fs RMS ultra-low jitter and down to 250 μV ensures fast, accurate and consistent jitter measurements
Access to over 50 built-in standard templates and automatic template margin analysis
Easily measure multiple signals simultaneously; analyze and acquire up to 16 signals simultaneously
Mainframe is upgradeable and backward compatible, providing full protection for your investment
The 86100D DCA-X is designed to provide the best combination of wide bandwidth, low noise, high reliability and high stability. The best combination of wide band, low noise and low jitter, thus enabling measurement of the true performance of the product.
By adding the option SIM InfiniiSim-DCA, it is possible to eliminate signal attenuation due to fixtures or cables, or Signal attenuation due to fixtures or cables can be eliminated, or de-embedded, providing more margin. Alternatively, it can
also be possible to simulate the signal at the end of the fixture or cable (embedding) for additional insight or compliance.
The 86100D DCA-X includes two user interfaces for greater ease of use. ease of use and is 100% backward compatible with the 86100C DCA-J
DCA-J. Switch between FlexDCA (the new vector-based interface) and the classic DCA user interface with just a touch of the screen.
Switch between the interface and the classic DCA user interface with the touch of a button.
FlexDCA user interface
Un-embedding, using option SIM embedding
Jitter on long mode (PRBS31), DDPWS, J2, J9, use
86100D option 200/401
Graphical signal processing
Up to 64 simultaneous determinations
"Classic" DCA user interface
Provides 100% backward compatibility
The 86100C DCA-J shares the familiar user interface used on the earlier 86100C series oscilloscopes. Familiar user interface used on series oscilloscopes
Eye diagram analysis and shield testing (standard on every 86100D) quickly and accurately characterize high-speed transmitters and transceivers. Accurate characterization of high-speed transmitters and transceivers. Eye diagram/mask mode is provided.
Accurate extinction ratio and eye diagram measurements
Industry standard mask testing with built-in margin analysis
1" and "0" levels, jitter, rise or fall times, etc.
Simultaneous acquisition on up to 16 channels provides
Highest throughput
Parallel mask testing on up to 16 channels
The 86100D DCA-X performs accurate measurements of high-speed digital designs, from 50MBd to over 80GBd, on up to 16 channels simultaneously. Accurate measurements of high-speed digital designs from 50MBd to over 80GBd on up to 16 channels.
Optical Transceiver Design and Production Testing
Electronic ASIC/FPGA/IC design and qualification
Serial bus qualification, measurement, and troubleshooting with TDR/TDT and S-parameters Channel, cable, and PCB measurements
Keysight offers a complete digital communications analyzer solution that can be used in conjunction with or alongside the DCA-X. Includes clock recovery, standalone Digital Communications Analyzer (DCA-M), and software.
Model: 86100D
Name: Infiniium DCA-X Wide Bandwidth Oscilloscope Mainframe
Brand:KEYSIGHT
Category: General Electronics Test > Oscilloscope
Product attributes: Mainframe
Features
90 GHz bandwidth
Custom host for optical, electrical and TDR/S parameter analysis
100 fs RMS ultra-low jitter and down to 250 μV ensures fast, accurate and consistent jitter measurements
Access to over 50 built-in standard templates and automatic template margin analysis
Easily measure multiple signals simultaneously; analyze and acquire up to 16 signals simultaneously
Mainframe is upgradeable and backward compatible, providing full protection for your investment
The 86100D DCA-X is designed to provide the best combination of wide bandwidth, low noise, high reliability and high stability. The best combination of wide band, low noise and low jitter, thus enabling measurement of the true performance of the product.
By adding the option SIM InfiniiSim-DCA, it is possible to eliminate signal attenuation due to fixtures or cables, or Signal attenuation due to fixtures or cables can be eliminated, or de-embedded, providing more margin. Alternatively, it can
also be possible to simulate the signal at the end of the fixture or cable (embedding) for additional insight or compliance.
The 86100D DCA-X includes two user interfaces for greater ease of use. ease of use and is 100% backward compatible with the 86100C DCA-J
DCA-J. Switch between FlexDCA (the new vector-based interface) and the classic DCA user interface with just a touch of the screen.
Switch between the interface and the classic DCA user interface with the touch of a button.
FlexDCA user interface
Un-embedding, using option SIM embedding
Jitter on long mode (PRBS31), DDPWS, J2, J9, use
86100D option 200/401
Graphical signal processing
Up to 64 simultaneous determinations
"Classic" DCA user interface
Provides 100% backward compatibility
The 86100C DCA-J shares the familiar user interface used on the earlier 86100C series oscilloscopes. Familiar user interface used on series oscilloscopes
Eye diagram analysis and shield testing (standard on every 86100D) quickly and accurately characterize high-speed transmitters and transceivers. Accurate characterization of high-speed transmitters and transceivers. Eye diagram/mask mode is provided.
Accurate extinction ratio and eye diagram measurements
Industry standard mask testing with built-in margin analysis
1" and "0" levels, jitter, rise or fall times, etc.
Simultaneous acquisition on up to 16 channels provides
Highest throughput