Other | Mega - Test and Measurement Technology Services, Inc.
Other | Mega - Test and Measurement Technology Services, Inc.

2601B-PULSE

Source Measurement Unit (SMU)
• Voltage output range: 0 to 200 V (pulse mode) / ±40 V (DC mode)
• Current output range: ±10 A (pulse peak) / ±1 A (DC continuous)
• Power resolution: 1 μW (equivalent to 0.001 dBm) @ 1550 nm optical device testing
• Four-quadrant operation: Supports bidirectional current sourcing/sinking (optimized for photovoltaic device testing)
Other | Mega - Test and Measurement Technology Services, Inc.
Other | Mega - Test and Measurement Technology Services, Inc.

2634B

Source Measurement Unit (SMU)
• Basic accuracy: ±0.012% (voltage source), ±0.034% (current source)
• High-speed sampling: 1 MS/s (18-bit ADC, storage depth 2 M points)
• Pulse mode: Minimum pulse width 50 μs (10 A pulse with programmable duty cycle)
• Output impedance: <10 mΩ (current source mode), >10 GΩ (voltage source mode)
• Communication interface: LAN/USB/GPIB (supports TSP-Link multi-machine synchronization)
Other | Mega - Test and Measurement Technology Services, Inc.
Other | Mega - Test and Measurement Technology Services, Inc.

2635B

Source Measurement Unit (SMU)
• Source/Measurement Range: 0.1 pA to 10 A / 100 nV to 200 V (DC or pulse mode)
• Wavelength Adaptation: 1250–1650 nm (requires external photodetector module, such as Model 2939 option)
• Power measurement accuracy: ±0.03 dB (when used with a calibrated InGaAs detector at 23°C ±5°C)
• Detector interface: Supports external FC/APC or SC/PC fiber couplers (requires an adapter module)
• Calibration standard: NIST-traceable voltage/current reference (with built-in self-calibration function)
• Maximum input protection: 200 V/10 A (automatic overload protection)
Other | Mega - Test and Measurement Technology Services, Inc.
Other | Mega - Test and Measurement Technology Services, Inc.

2611B

Source Measurement Unit (SMU)
• Wavelength range: 1250–1650 nm (covers O/E/S/C/L band single-mode fiber optic communications)
• Power measurement range: -70 dBm to +23 dBm (automatic range switching, supports high dynamic range)
• Measurement accuracy: ±0.03 dB (typical value, after NIST-traceable calibration, at 23°C ±5°C environment)
• Resolution: 0.01 dB (high-precision mode) / 0.1 dB (fast mode)
Other | Mega - Test and Measurement Technology Services, Inc.
Other | Mega - Test and Measurement Technology Services, Inc.

2425

Other
• Power output range: 0 to 105 V / 0 to 1.05 A (DC or pulse mode)
• Power output capacity: Maximum 20 W (continuous mode), 40 W (pulse mode)
• Four-quadrant operation: Supports source/sink bidirectional current (positive and negative voltage and current)
• Voltage measurement range: 0 to 105 V (automatic range)
• Current measurement range: 10nA to 1.05A (7-range automatic switching)
Other | Mega - Test and Measurement Technology Services, Inc.
Other | Mega - Test and Measurement Technology Services, Inc.

34972A keysight

Data Acquisition/Module
- 3-slot mainframe with USB and LAN ports
- 6 1/2-bit (22 bit) built-in digital multimeter that can scan up to 250 channels per second
- 8 plug-in switch and control modules available
Other | Mega - Test and Measurement Technology Services, Inc.
Other | Mega - Test and Measurement Technology Services, Inc.

IT2800 ITECH

Source Measurement Unit (SMU)
- Multi-channel synchronization with parallel test capability
- Built-in resistance, power and Math measurement functions
- GUARD output for low-current measurements
- Front USB port for data storage, screenshots or test configuration import.
- Built-in USB/LAN/Digital 10 and optional GPIB.
Other | Mega - Test and Measurement Technology Services, Inc.
Other | Mega - Test and Measurement Technology Services, Inc.

Other | Mega - Test and Measurement Technology Services, Inc.
Other | Mega - Test and Measurement Technology Services, Inc.

Source Measurement Unit (SMU)
 2 3 4 5 6 7 8 ... 11