Options CR-1.063, 1.250, 2.488 and 2.500 GHz clock recovery
2.5 GHz optical bandwidth
Number of input channels: 1
Effective wavelength range: 700 nm to 1650 nm
Calibration wavelengths: 780 nm, 850 nm, 1310 nm, and 1550 nm
Absolute maximum non-destructive optical input: 10 mW peak non-destructive optical input at the wavelength of highest relative responsiveness
Tektronix 8000 Series sampling oscilloscopes configured with one or more optical sampling modules provide a complete optical test solution for telecom (622 Mb/s to 9.953 Gb/s) or datacom (Fibre Channel and Gigabit Ethernet) applications and general purpose optical component testing. Each optical module includes all the components required for optical testing.
The 80C03-CR module supports waveform compliance testing of short-wave and long-wave (700-1650 nm) signals at 1.063, 1.250 and 2.488 Mb/s speeds, as well as general purpose testing up to 2.3 GHz optical bandwidth. Its amplified optoelectronic converter design enables users to detect very low optical signals.
The 80C03-CR is optionally configurable with clock recovery (Opt.CR) and supports Fibre Channel 1063 (1.063 Gb/s), Gigabit Ethernet (1.250 Gb/s) and OC48/STM16 (2.488 Gb/s) standards.