Yokogawa AQ6370D-12 vs AQ6370D-22 Spectrum Analyser Difference?

2024-06-24
View:496

The main difference between the Yokogawa AQ6370D-12 and the AQ6370D-22 lies in their model numbers and possible differences in features or specifications?The Yokogawa AQ6370D series consists of a number of models such as the AQ6370D-02, the AQ6370D-12 and the AQ6370D-22.


In terms of wavelength range, high wavelength accuracy, high wavelength resolution, large dynamic range and wide power range, the Yokogawa AQ6370D series spectrum analysers have high performance specifications, such as a wavelength range of 600~1700nm, a high wavelength accuracy of ±0.01nm, a high wavelength resolution of 0.02nm, a large dynamic range of 78dB (typical). Wide power range of +20~-90dBm, fast measurement time of 0.2 seconds (100nm span).


What are the specific differences in wavelength range between the AQ6370D-12 and the AQ6370D-22?

The specific differences are listed below:

The wavelength range of the AQ6370D-12 is 600~1700nm .

The wavelength range of AQ6370D-22 covers 1200~2400nm .

The wavelength range of AQ6370D-12 is narrower than that of AQ6370D-22.


What are the results of dynamic range and power range comparison between AQ6370D-12 and AQ6370D-22?

Dynamic Range:


Typical for the AQ6370D is 78dB .


Power Range:


The AQ6370D has a wide power range of +20 to -90dBm .



Yokogawa AQ6370D-12 vs AQ6370D-22 Spectrum Analyser Difference?
2024-06-24

The main difference between the Yokogawa AQ6370D-12 and the AQ6370D-22 lies in their model numbers and possible differences in features or specifications?The Yokogawa AQ6370D series consists of a number of models such as the AQ6370D-02, the AQ6370D-12 and the AQ6370D-22.


In terms of wavelength range, high wavelength accuracy, high wavelength resolution, large dynamic range and wide power range, the Yokogawa AQ6370D series spectrum analysers have high performance specifications, such as a wavelength range of 600~1700nm, a high wavelength accuracy of ±0.01nm, a high wavelength resolution of 0.02nm, a large dynamic range of 78dB (typical). Wide power range of +20~-90dBm, fast measurement time of 0.2 seconds (100nm span).


What are the specific differences in wavelength range between the AQ6370D-12 and the AQ6370D-22?

The specific differences are listed below:

The wavelength range of the AQ6370D-12 is 600~1700nm .

The wavelength range of AQ6370D-22 covers 1200~2400nm .

The wavelength range of AQ6370D-12 is narrower than that of AQ6370D-22.


What are the results of dynamic range and power range comparison between AQ6370D-12 and AQ6370D-22?

Dynamic Range:


Typical for the AQ6370D is 78dB .


Power Range:


The AQ6370D has a wide power range of +20 to -90dBm .