The Keysight N1077B is an optical/electrical clock recovery device that supports a data rate range of 115 MBd to 24 GBd for multimode and singlemode optical signals as well as electrical signals. The device is capable of handling both PAM4 and NRZ data signal types and provides standards-compliant clock recovery.
Model No.: N1077B/A
Name: Optical/Electrical Clock Recovery
Brand:Keysight
Category:General Electronic Test >Optical/Electrical Clock Recovery
Product Attributes:Host
Features
125 MBd to 64 GBd data rate range (continuous) with optical/electrical NRZ and PAM4 data signal support
Adjustable peak and loop bandwidths (up to 20 MHz) provide standards-compliant clock recovery (‘Ideal PLL’)
Built-in equaliser (option EVA) locks out signals with degraded quality (‘closed eye view’)
Jitter spectrum analysis function (option JSA) for in-depth analysis of the root cause of jitter
Performs specification-compliant PLL bandwidth and peak measurements using the N1010300A FlexPLL application software
Performance in different application scenarios
Multimode Optical Integrated Clock Recovery Module: The N1077B is a multimode optical integrated multimode clock recovery module that supports short-range multimode clock recovery for 100G/400G/800G applications, including single-wave 100G clock recovery. This demonstrates its ability to handle high-speed data transmission and clock signal recovery, an important advantage for high-speed network equipment requiring high-precision clock recovery.
Optical/Electrical Clock Recovery Capability: The N1077B is equipped with an optical/electrical clock recovery function, which allows it to receive incoming data or clock signals and lock and output the recovered clock using a phase-locked loop (PLL) circuit. This capability makes it suitable for a variety of applications that require precise clock synchronisation, such as communications systems, test equipment and other electronic measurement devices.
Specifications and Connectivity: The N1077B's DCA-M specifications and features are suitable for operation over a temperature range. It connects to a DCA-X host or N1010A FlexDCA via a USB 2.0 device, a connection that provides flexibility and convenience, allowing users to easily integrate the N1077B into existing test and measurement systems.
Application Areas: Although specific application areas are not specified in detail, the technical specifications and functions suggest that the N1077B may be widely used in communications testing, performance verification of network equipment, and other specialised areas that require high-precision clock recovery.
The Keysight N1077B is an optical/electrical clock recovery device that supports a data rate range of 115 MBd to 24 GBd for multimode and singlemode optical signals as well as electrical signals. The device is capable of handling both PAM4 and NRZ data signal types and provides standards-compliant clock recovery.
Model No.: N1077B/A
Name: Optical/Electrical Clock Recovery
Brand:Keysight
Category:General Electronic Test >Optical/Electrical Clock Recovery
Product Attributes:Host
Features
125 MBd to 64 GBd data rate range (continuous) with optical/electrical NRZ and PAM4 data signal support
Adjustable peak and loop bandwidths (up to 20 MHz) provide standards-compliant clock recovery (‘Ideal PLL’)
Built-in equaliser (option EVA) locks out signals with degraded quality (‘closed eye view’)
Jitter spectrum analysis function (option JSA) for in-depth analysis of the root cause of jitter
Performs specification-compliant PLL bandwidth and peak measurements using the N1010300A FlexPLL application software
Performance in different application scenarios
Multimode Optical Integrated Clock Recovery Module: The N1077B is a multimode optical integrated multimode clock recovery module that supports short-range multimode clock recovery for 100G/400G/800G applications, including single-wave 100G clock recovery. This demonstrates its ability to handle high-speed data transmission and clock signal recovery, an important advantage for high-speed network equipment requiring high-precision clock recovery.
Optical/Electrical Clock Recovery Capability: The N1077B is equipped with an optical/electrical clock recovery function, which allows it to receive incoming data or clock signals and lock and output the recovered clock using a phase-locked loop (PLL) circuit. This capability makes it suitable for a variety of applications that require precise clock synchronisation, such as communications systems, test equipment and other electronic measurement devices.
Specifications and Connectivity: The N1077B's DCA-M specifications and features are suitable for operation over a temperature range. It connects to a DCA-X host or N1010A FlexDCA via a USB 2.0 device, a connection that provides flexibility and convenience, allowing users to easily integrate the N1077B into existing test and measurement systems.
Application Areas: Although specific application areas are not specified in detail, the technical specifications and functions suggest that the N1077B may be widely used in communications testing, performance verification of network equipment, and other specialised areas that require high-precision clock recovery.